Udo, Dhr. D. (Dirk) wrote:
I installed a second management server and everything works fine except
the logging when I switch machines. 2th server doesn't log from nokia's.
Any ideas? The message is as follows
Install Database on server-y Log Server can only be partially completed.
To restore full functionality (full resolving and remote operations),
upgrade the Log Server to be the same version as your Management Server.
Regards,
Dirk.
Hi Dirk,
do both SmartCenters run on the same OS? This is necessary. No problems
will occur, if they are also the same version of CP, but this isn't
mandantory. The Management has to be on the highest version level, so
R55 Firewalls can't really log to a NG FP2 Management Server.
Do you have checked the configuration of your Firewall Modules? Are the
entries in CP object - Logs and Masters - Log Servers correct?
Hope it helps,
best regards,
Matthias
http://www.fw-1.de
--